StarTech.com ECS0016 Instrukcja Obsługi

Przeglądaj online lub pobierz Instrukcja Obsługi dla Przełączniki KVM StarTech.com ECS0016. StarTech.com ECS0016 KVM switch Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Enhanced Console Server

ECS0016Enhanced Console Server

Strona 2

Instruction Manual3Management Console ConnectionThe ECS0016 is pre-configured with a default IP Address: 192.168.0.1 and Subnet Mask: 255.255.255.0 . D

Strona 3 - Table of Contents

Instruction Manual93The config tool is designed to perform multiple actions from one com-mand if need be, so if necessary options can be chained togeth

Strona 4

Instruction Manual94 LDAP Base Node: Some base node #/bin/cong–-set=”cong.auth.ldap.basenode=somebasenode”The following command will synchr

Strona 5

Instruction Manual95 The following command will synchronize the live system with the new configuration: #/bin/cong–-run=timeTime ZoneTo change the

Strona 6

Instruction Manual96IP Configuration - StaticTo set static configuration on the LAN interface with the following at-tributes (denoted in bolded text), y

Strona 7

Instruction Manual97The following command will synchronize the live system with the new configuration. #/bin/cong–-run=ipcongDial-in ConfigurationT

Strona 8 - Introduction

Instruction Manual98‘115200’, and ‘230400’.Supported parity values are ‘None’, ‘Odd’, ‘Even’, ‘Mark’ and ‘Space’.Supported data-bits values are ‘8’, ‘

Strona 9 - Initial Conguration

Instruction Manual99 Please Note: “/bin/config” commands can be combined into one com-mand for convenience.Serial Port ConfigurationSerial Port Settings

Strona 10 - Management Console Connection

Instruction Manual100Supported stop-bits values are ‘1’, ‘1.5’ and ‘2’.Supported flow-control values are ‘Hardware’, ‘Software’ and ‘None’.Supported Pr

Strona 11

Instruction Manual101Note that if you see: cong.users.total it means you have 0 Users configured.So, your new User will be the exist

Strona 12

Instruction Manual102 cong.portaccess.total it means you have 0 rules configured. Your new rule will be the existing total plus

Strona 13 - Administrator Password

Instruction Manual4ARPPing IP Address AssignmentIf it is not convenient to change the PC/workstation network address, you can use the ARP-Ping command

Strona 14 - Network IP address

Instruction Manual103The following command will synchronize the live system with the new configuration. #/bin/cong–-run=eventlog Please note that s

Strona 15 - System Services

Instruction Manual104The following command will synchronize the live system with the new configuration: #/bin/cong–-run=alertsMetaConnect Host Confi

Strona 16

Instruction Manual105    <user1>JohnWhite</user1>   </users>   <tcpports><tcpport1>23</tcpport1></tcp

Strona 17

Instruction Manual106History:Typing the character sequence ‘~h’ will generate a history on the serial port.Quitpmshell:Typing the character sequence

Strona 18 - Communications Software

Instruction Manual107Example:To detect which users are currently active on which serial ports: #pmusersThis command will output nothing if there are

Strona 19

Instruction Manual108 Change which configuration file it uses: -c/etc/cong/portmanager.confSignalsSending a SIGHUP signal to the portmanager will ca

Strona 20

Instruction Manual109 example: </etc/cong/pmshell-start.sh> #!/bin/sh PORT=”$1” USER=”$2” echo“Welcometoport$PORT$USER” </etc/

Strona 21 - Conguring Serial Ports

Instruction Manual110Raw Access to Serial PortsAccess to Serial PortsYou can tip and stty to completely bypass the portmanager and have raw access to

Strona 22

Instruction Manual111Modem initialization strings• To override the standard modem initialization string either use the Management Console o

Strona 23

Instruction Manual112The basic steps performed are as follows:a) The current iptables configuration is erased.b) If a customized IP-Filter script exist

Strona 24

Instruction Manual5You will be prompted to log in. Enter the default administration username and administration password: Username:

Strona 25

Instruction Manual113   –-matchstate–-stateESTABLISHED,RELATED–-jumpACCEPT #Explicitlyacceptanyconnectionsfromcomputerson #192.168.1

Strona 26

Instruction Manual114Adding more than one SNMP server To add more than one SNMP server for alert traps add the first SNMP server using the Management C

Strona 27

Instruction Manual115To set the Username field (SNMP version 3 only): congsetcong.system.snmp.username2=yourusername.. (replacing yourusernam

Strona 28

Instruction Manual116powerman - power on/off nodes Synopsispowerman [-option] [targets]pm [-option] [targets] Options-1,--on Power ON targets. -0,

Strona 29 - Add / Edit Users

Instruction Manual117-h,--help Display option summary. -L,--license Show powerman license information. -d,--destinationhost[:port] Connect to a

Strona 30

Instruction Manual118As a reminder to the reader, some shells will interpret brackets ([ and ]) for pattern matching. Depending on your shell, it may

Strona 31 - Authentication

Instruction Manual119Default system Power Device actions are specified in /etc/powerstrips.xml. Custom Power Devices can be added in /etc/config/powerst

Strona 32 - Network Hosts

Instruction Manual120 <off>script to power off</off> <cycle>script to cycle power</cycle> <status>script to wri

Strona 33 - Trusted Networks

Instruction Manual121Glossary of Terms UsedTERM MEANINGAuthentication Authentication is the technique by which a process verifies that its communicatio

Strona 34 - Serial Port Cascading

Instruction Manual122TERM MEANINGCertificate Authority A Certificate Authority is a trusted third party, which certifies public key's to truly belon

Strona 35

Instruction Manual6Administrator PasswordFor security reasons, only the Administrator (the administration user named root) can initially log into your

Strona 36

Instruction Manual123TERM MEANINGFirewall A network gateway device that protects a private network from users on other networks. A firewall is usually

Strona 37

Instruction Manual124TERM MEANINGKey lifetimes The length of time before keys are renegotiated LAN Local Area Network LDAP The Lightweight Directory A

Strona 38

Instruction Manual125TERM MEANINGNAT Network Address Translation. The translation of an IP address used on one network to an IP address on another net

Strona 39 - Remote Power Control (RPC)

Instruction Manual126TERM MEANINGRADIUS The Remote Authentication DialIn User Service (RADIUS) protocol was developed by Livingston Enterprises as an

Strona 40

Instruction Manual127TERM MEANINGSOL Serial Over LAN (SOL) enables servers to transparently redirect the serial character stream from the baseboard un

Strona 41

Instruction Manual128TERM MEANINGTelnet Telnet is a terminal protocol that provides an easytouse method of creating terminal connec-tions to a network

Strona 42

Instruction Manual129Technical SpecicationsFEATURE VALUE Dimensions 17 x 8.5 x 1.75 in (43.2 x 21. x 4.5 cm)Weight 3.9 kg (8.5 lbs) Ambient operatin

Strona 43

Instruction Manual130RJ45 Connector - PinoutWiringPin Signal Direction RS232 Signal Description1 RTS Output Request To Send2 DSR Input Data Set Ready3

Strona 44

Instruction Manual131Adapter (included Part # 319000) Pinout - (Straight through)Accessory (included Part # 319001) Pinout - (Crossover)Additional ad

Strona 45

Instruction Manual132Technical SupportStarTech.com’s lifetime technical support is an integral part of our commit-ment to provide industry-leading sol

Strona 46

Instruction Manual7Network IP addressYou now must enter an IP address for the principal Ethernet (LAN/Net-work/Network1) port on the ECS0016 gateway,

Strona 47

StarTech.com has been making “hard-to-find easy” since 1985, providing high quality solutions to a diverse IT and A/V customer base that spans m

Strona 48

Instruction Manual8By default the ECS0016 LAN port auto detects the Ethernet connection speed. However you can use the Media menu to lock the Ethernet

Strona 49

Instruction Manual9HTTPSThis ensures secure browser access to all of the Management Console menus. It also allows appropriately configured Users secure

Strona 50

Instruction Manual10There are also a number of related service options that can be configured at this stage: SNMPThis will enable netsnmp in the gatewa

Strona 51

Instruction Manual11Communications SoftwareYou have configured access protocols for the Administrator client to use when connecting to the ECS0016. Use

Strona 52 - Environmental Monitoring

Instruction Manual12MetaConnect is a Java client program that couples the SSH tunneling protocol with popular access tools such as Telnet, SSH, HTTP,

Strona 53

FCC Compliance StatementThis equipment has been tested and found to comply with the limits for a Class B digital de-vice, pursuant to part 15 of the F

Strona 54

Instruction Manual13SSHTermAnother common communications package that may be useful is SSH-Term, an open source package that can be downloaded from h

Strona 55

Instruction Manual14Conguring Serial PortsTo configure the serial port, you must first set the protocols and the RS232 parameters that are to be used f

Strona 56

Instruction Manual15When you have reconfigured the common settings and the mode for • each port, you set up any remote syslog, then click Apply Comm

Strona 57 - OoB Dial-In access

Instruction Manual16Before proceeding with further serial port configuration, you should • connect the ports to the serial devices they will be cont

Strona 58

Instruction Manual17From Win2000/XP/NT, you can run telnet from the command prompt • (cmd.exe)You can also use standard communications packages lik

Strona 59

Instruction Manual18SSH It is recommended that you use SSH as the protocol whereby the User or Administrator connects to the ECS0016 gateway (or conn

Strona 60

Instruction Manual19For a User named ‘Paul’ to access serial port 2, when setting up the SSHTerm or the PuTTY SSH client, instead of typing username =

Strona 61

Instruction Manual20RFC2217 also enables the serial port to be tunneled to a remote ECS0016 client gateway, so two serial port devices can be transpar

Strona 62

Instruction Manual21Data Carrier Detect (DCD) pin on the serial device being raised. When a connection is detected, the getty program issues a login:

Strona 63

Instruction Manual22can also be configured to support the remote syslog protocol on a per serial port basis.Select the Syslog Facility/Priority fields t

Strona 64

Instruction ManualiInstruction ManualTable of ContentsIntroduction ...

Strona 65

Instruction Manual23Select 1. Serial & Network: Users & Groups to display the configured Groups and Users Click 2. Add Group.Add a 3. Gro

Strona 66

Instruction Manual24 The Administrator can also edit the Access settings for any existing Us-ers. To do so:Select 1. Serial & Network: Users &am

Strona 67

Instruction Manual25Network HostsTo access a locally networked computer or appliance (referred to as a Host) you must identify the network connected H

Strona 68

Instruction Manual26Trusted NetworksThe Trusted Networks utility provides the option to select specific IP addresses at which users (Administrators and

Strona 69

Instruction Manual27 Network IP Address: 204.15.5.128 Subnet Mask: 255.255.255.224Click 6. Apply.The above Trusted Networks will limit acces

Strona 70

Instruction Manual28 Next, you must register the Public Key as an Authorized Key on the 5. Slave. In the simple case with only one Master with mult

Strona 71 - Alerts and Logging

Instruction Manual29The next step is to Fingerprint each new Slave-Master connection, which will authenticate you as a legitimate user for the SSH ses

Strona 72

Instruction Manual30 of clustered console servers and the connected devices) Enter the full number of serial ports on the Slave unit in Number of 3.

Strona 73

Instruction Manual31 next time the Master sends out a configuration file update. Also, while the Master is in control of all Slave serial port related

Strona 74

Instruction Manual32Remote Power Control (RPC) The ECS0016 Management Console monitors and controls Remote Power Control devices using the embedded Po

Strona 75 - Power Control

Instruction ManualiiSerial Port and Network Host Configuration... 13Configuring Serial Ports ...

Strona 76

Instruction Manual33Select the Serial & Network: RPC Connections menu. This will display 3. all the RPC connections that have already been configur

Strona 77

Instruction Manual34Enter the Username and Password used to login into the RPC (Note 8. that these login credentials are not related the Users and ac

Strona 78

Instruction Manual35Click on View Log or select the 2. RPCLogs menu and you will be presented with a table of the history and detailed graphical info

Strona 79 - Nagios Integration

Instruction Manual36The outlet status is displayed and you can initiate the desired Action to be taken by selecting the appropriate icon: Power ON Pow

Strona 80

Instruction Manual37The console server may or may not be drawing power through the Managed UPS (see the Configure UPS powering the console server secti

Strona 81

Instruction Manual38Enter a 4. UPS Name and Description (optional) and the select if the UPS will be Connected Via USB or over pre-configured serial p

Strona 82

Instruction Manual39positive number, or -1. 0s are shut down first, then 1s, 2s, etc. -1s are not shut down at all. Defaults to 0Select the Driver th

Strona 83

Instruction Manual40If the ECS0016 is drawing power through a Managed UPS that has already been configured, select Local, enter the Managed UPS Name an

Strona 84

Instruction Manual41Configuring Powered Computers to Monitor a Managed UPS Once you have added a Managed UPS, each server that is drawing power through

Strona 85

Instruction Manual42- username is the Username of the Managed UPS- password is the Password of the Manager UPSUPS Alerts You can now set UPS alerts us

Strona 86

Instruction ManualiiiSetting up MetaConnect for Remote Desktop access ...61Set up MetaConnect Serial Ports on ECS0016 ...

Strona 87

Instruction Manual43Select UPS Logs and you will be presented with the log table of the 4. load, battery charge level. temperature and other status in

Strona 88

Instruction Manual44NUT is built on a networked model with a layered scheme of drivers, server and clients. The driver programs talk directly to the U

Strona 89 - System Management

Instruction Manual45status of a UPS, writing it to a file. All these clients all run on the ECS0016 (for Management Console presentations) but they al

Strona 90

Instruction Manual46Using the Management Console, Administrators can view the ambient temperature and humidity and set the EMD to automatically send a

Strona 91

Instruction Manual47 Screw the bare wires on any smoke detector, 2. water detector, vibration sensor, open-door sensor or general purpose open/close

Strona 92 - Status Reports

Instruction Manual48Enter a 5. Name and Description for the EMD and select pre-configured serial port that the EMD will be “Connected Via”.Provide 6.

Strona 93

Instruction Manual49Environmental Status You can monitor the current status of all of EMDs and their probesSelect the 1. Status: Environmental Status

Strona 94

Instruction Manual50Failover and Out-of-Band Dial AccessThe ECS0016 has a number of failover and out-of-band access capabili-ties to ensure high avail

Strona 95 - Management

Instruction Manual51Please note: The ECS0016 requires an external modem attached (via a serial cable) to the DB9 port (marked Local, located on the fr

Strona 96

Instruction Manual52Select the 6. Authentication Type to be applied to the dial-in connection.The ECS0016 uses authentication to challenge Administra

Strona 97

Instruction ManualivStatus Reports ... 85Port Access and Active Users ...

Strona 98

Instruction Manual53ECS0016 gateways also support dial-back for additional security. Check the Enable Dial Back box and enter the phone number to be c

Strona 99

Instruction Manual54Similarly for Windows® 98, you double-click My Computer on the Desk-top, then open Dial-Up Networking and double-click Make New Co

Strona 100 - Instruction Manual

Instruction Manual55Command line PPP and manual configuration (which works with any • Linux distribution) Using the Linuxconf configuration tool (f

Strona 101

Instruction Manual56Secure Tunneling & MetaConnectTelnet or SSH connection to serially attached devices MetaConnect can also be used to access tex

Strona 102

Instruction Manual57 then Close and Close again Assuming you have already set up the target ECS0016 as a gateway 3. in your MetaConnect client (wi

Strona 103

Instruction Manual58Select 1. Users & Groups from Serial & Network.Click 2. Add User. Enter a 3. Username, Description and Password/Confirm.

Strona 104

Instruction Manual59To initiate a pre-configured dialup connection under Windows, use the • following Start Command: cmd /c start “Starting Out

Strona 105

Instruction Manual60To make the OoB connection using MetaConnect:Select the gateway from the left hand list of gateways and hosts. Under Gateway Actio

Strona 106

Instruction Manual61 PuTTYgen: http://www.chiark.greenend.org.uk/~sgtatham/putty/download.html OpenSSH: http://www.openssh.org/ OpenSSH (Wind

Strona 107

Instruction Manual62system, reboot the machine etc. ECS0016’s Secure Tunneling uses SSH tunneling, so this RDP traffic is securely transferred through

Strona 108

Instruction ManualvRaw Access to Serial Ports ...110Access to Serial Ports ...

Strona 109

Instruction Manual63ration protocols on that portNote: If you leave the Username and User Password fields blank, they default to portXX and portXX wher

Strona 110

Instruction Manual64Alerts and LoggingThis chapter describes the logging and alert generation features of the console server. The Alert facility monit

Strona 111

Instruction Manual65SNMP alertsThe Administrator can configure the Simple Network Management Proto-col (SNMP) agent that resides on the console server,

Strona 112 - Advanced Conguration

Instruction Manual66emailed to a nominated email address, or the SNMP or Nagios server is notified. The data stream from nominated serial ports can be

Strona 113

Instruction Manual67disconnects from the applicable Host or Serial Port, or when a Slave con-nects or disconnects from the applicable UPS Serial Port

Strona 114

Instruction Manual68port activity. These records are stored on an ‘offserver’. To specify which serial ports are to have activities recorded and to wh

Strona 115 - External Scripts and Alerts

Instruction Manual69 when connected using MetaConnect. These IPMI controlled power switches can also be controlled using the Management Consol

Strona 116

Instruction Manual70Configuring Serial Port Power StripsThe Administrator can configure serially connected power strips, so both Users and Administrator

Strona 117 - Raw Access to Serial Ports

Instruction Manual71Configuring Browser Controlled Power StripsThe Administrator can configure network attached power strips, so both Users and Administ

Strona 118

Instruction Manual72Nagios IntegrationNagios is a powerful, highly extensible open source tool for monitoring network hosts and services. The core Nag

Strona 119

Instruction Manual1IntroductionThank you for purchasing a StarTech.com Conyx ECS0016 Enhanced Console Server. This innovative remote service manageme

Strona 120

Instruction Manual73it provides an outstanding network monitoring system. With Nagios you can: Display tables showing the status of each monitored ser

Strona 121

Instruction Manual74Clients Typically a client PC, laptop, etc. running Windows, Linux or Mac OS X •Runs MetaConnect •Possibly remote to the central

Strona 122 - Power Strip Control

Instruction Manual75You will also require a web server such as Apache to display the Nagios web UI (and this may be installed automatically as a depen

Strona 123

Instruction Manual76The first step is to set up the Nagios features on the console server:Select 1. System: Nagios on the ECS0016 Management Console.

Strona 124

Instruction Manual77 Host. Enter the 2. IP Address/DNS Name of the network server, e.g.: 192.168.1.10 and enter a Description, e.g.: Windows 2003

Strona 125

Instruction Manual78 port attached. In Applicable Hosts, check the IP address/DNS name of the IIS server. Click 13. Connection Alert.Click 14

Strona 126

Instruction Manual79 upstream Nagios server will use to reach the ECS0016 – if unspecified this will default to the first network port’s IP (Network

Strona 127

Instruction Manual80Enable NSCA monitoringNSCA is the mechanism that allows you to send passive check results from the remote ECS0016 to the Nagios da

Strona 128 - Glossary of Terms Used

Instruction Manual81Select 4. Check Permitted TCP/UDP to monitor a service that you have previously added as a Permitted Service. Select 5. Check

Strona 129

Instruction Manual82System ManagementThis chapter describes how the Administrator can perform a range of general ECS0016 system administration and con

Strona 130

Instruction Manual2Initial CongurationUnpack the ECS0016 kit and verify you have all of the parts indicated in the Package Contents list shown on the

Strona 131

Instruction Manual83ton gently twice (within a 5 second period) while the unit is powered ON.This will reset the ECS0016 back to its factory default s

Strona 132

Instruction Manual84Configure Date and TimeIt is recommended that you set the local Date and Time in the ECS0016 as soon as it is configured. Features l

Strona 133

Instruction Manual85Status ReportsThis chapter describes the selection of status reports that are available for review:Port Access and Active Users •

Strona 134

Instruction Manual86StatisticsThe Statistics report provides a snapshot of the data traffic and other activities and operations of your gateway.Support

Strona 135

Instruction Manual87SyslogThe Linux System Logger maintains a record of all system messages and errors. To view the System Log, select Status: Syslog

Strona 136 - Technical Specications

Instruction Manual88ManagementThe ECS0016 has a number of Management reports and tools that can be accessed by both Administrators and Users:Access an

Strona 137

Instruction Manual89Serial Port Terminal ConnectionAdministrator and Users can communicate directly with the ECS0016 command line and with devices att

Strona 138

Instruction Manual90The alternate to using MetaConnect and your local telnet client is to download the open source jcterm Java terminal applet into yo

Strona 139 - Warranty Information

Instruction Manual91 Configuration) Date and Time Configuration (Manually Change Clock Settings and • Network Time Protocol Time Zone) Network Config

Strona 140

Instruction Manual92The config Tool:Syntax config [ ahv ] [ d id ] [ g id ] [ p path ] [ r configurator ] [ s id=value ] DescriptionThe config tool all

Komentarze do niniejszej Instrukcji

Brak uwag